Products > 781 Series Breather Drain Plug

781 Series Breather Drain Plug

Available in brass, nickel plated brass, aluminium, stainless steel & nylon

Description

Technical

781 Breather Drain Plug, Globally Approved, Explosive Atmosphere Cable / Conduit Accessory

• 781E for Ex e use
• 781D for Ex d use
• Drains equipment susceptible to moisture collection
• Enables equipment to breathe
• General purpose / industrial version available
• Nylon Ex e only version available (-20°C to +60°C)
• -60°C to 130°C (metallic versions)
• Globally marked, IECEx, ATEX & cCSAus

 

HOW TO ORDER

e.g. 781 – D – M – 3 = Ex d – M25 e.g. 781 – E – M – 3 = Ex e – M25 Other Thread Variations are available on request. For further information on ordering please refer to page 150. The CMP 781E range of Increased Safety type ‘e’ breather / drain plugs have been tested together with CMP serrated washers to ensure that in areas that are subject to vibration the plug does not suffer from self-loosening and in advertently fall out of the enclosure. Serrated washers are not included as standard but can be ordered separately

Design SpecificationBS 6121:Part 1:1989, IEC 62444, EN 62444
Enclosure ProtectionIK10 to IEC 62262 (20 joules) Brass & Stainless Steel Only
ATEX CertificateSIRA 10 ATEX 1307U
Code of Protection781D: II 2G Ex d IIC Gb, II 1D Ex ta IIIC Da
781E: II 2G Ex e IIC Gb, II 1D Ex ta IIIC Da
Compliance StandardsEN 60079-0,1,7,31
IECEx CertificateIECEx SIR 10.0149U
Code of Protection781D: Ex d IIC Gb, Ex ta IIIC Da
781E: Ex e IIC Gb, Ex ta IIIC Da
Compliance StandardsIEC 60079-0,1,7,31
cCSAus Certificate1055233
Code of Protection781D: Ex d IIC, Class I, Zone 1 AEx d IIC; Class I Div 1, Groups A,B,C,D
IP66, Enclosure Type 4X
781E: Ex e II, Class I, Zone 1, AEx e II
IP66, Enclosure Type 4X
Compliance StandardsCSA C22.2 No 0-10, 0.5, 30, 94; e 60079-0,1,7, E61241-1-1, UL50, 1203, UL60079-0,1,7
UL CertificateE253914
Code of Protection781D: Class I, Zone 1 AEx d IIB; Zone 20 AEx ta IIIC
781E: Class I, Zone 1, AEx e IIC;
EAC Certificate (Formerly GOST R, K & B)TC RU C-GB.AA87.B.00487
GOST R CertificatePOCC.GB.35.H00102
CCOE / PESO (India) CertificateP333688
INMETRO CertificateTÜV 12.133OU
NEPSI CertificateGYJ13.1139X (781D), GYJ13.1138X (781E)
RETIE Approval03866
Marine ApprovalsLRS: 01/00173
Continuous Operating Temperature781D: -60°C to +130°C
781E: -60°C to +130°C (-20°C to +60°C Nylon)
Ingress Protection Rating **781D: IP66 (when fitted with CMP sealing accessories)
781E: IP66
Available MaterialsBrass, Nickel Plated Brass, Aluminium, Stainless Steel, Nylon (781E only)
Accessories Included (781E only)Integral Entry Thread equipment interface ‘O’ ring seal, Castellated Locknut

Product Table

Metric

Ordering Reference
(781D)
Ordering Reference
(781E)
Thread SizeMinimum Thread LengthProtrusion Length “F”Across Flats DimensionAcross Corners DimensionsMax Installation Torque (Nm)
781DM2781EM2M20 x 1.515.012.730.033.07
781DM3781EM3M25 x 1.515.012.736.039.610
781DT1781ET1½” NPT19.912.730.033.07
781DT2781ET2¾” NPT20.212.736.039.610
Dimensions displayed in millimeters unless otherwise stated

Imperial

Ordering Reference
(781D)
Ordering Reference
(781E)
Thread SizeMinimum Thread LengthProtrusion Length “F”Across Flats DimensionAcross Corners DimensionsMax Installation Torque (Nm)
781DM2781EM2M20 x 1.50.590.501.181.307
781DM3781EM3M25 x 1.50.590.501.421.5610
781DT1781ET1½” NPT0.780.501.181.307
781DT2781ET2¾” NPT0.800.501.421.5610
Dimensions displayed in inches unless otherwise stated

Download Spec Sheet

Download

Technical

781 Breather Drain Plug, Globally Approved, Explosive Atmosphere Cable / Conduit Accessory

• 781E for Ex e use
• 781D for Ex d use
• Drains equipment susceptible to moisture collection
• Enables equipment to breathe
• General purpose / industrial version available
• Nylon Ex e only version available (-20°C to +60°C)
• -60°C to 130°C (metallic versions)
• Globally marked, IECEx, ATEX & cCSAus

 

HOW TO ORDER

e.g. 781 – D – M – 3 = Ex d – M25 e.g. 781 – E – M – 3 = Ex e – M25 Other Thread Variations are available on request. For further information on ordering please refer to page 150. The CMP 781E range of Increased Safety type ‘e’ breather / drain plugs have been tested together with CMP serrated washers to ensure that in areas that are subject to vibration the plug does not suffer from self-loosening and in advertently fall out of the enclosure. Serrated washers are not included as standard but can be ordered separately

Design SpecificationBS 6121:Part 1:1989, IEC 62444, EN 62444
Enclosure ProtectionIK10 to IEC 62262 (20 joules) Brass & Stainless Steel Only
ATEX CertificateSIRA 10 ATEX 1307U
Code of Protection781D: II 2G Ex d IIC Gb, II 1D Ex ta IIIC Da
781E: II 2G Ex e IIC Gb, II 1D Ex ta IIIC Da
Compliance StandardsEN 60079-0,1,7,31
IECEx CertificateIECEx SIR 10.0149U
Code of Protection781D: Ex d IIC Gb, Ex ta IIIC Da
781E: Ex e IIC Gb, Ex ta IIIC Da
Compliance StandardsIEC 60079-0,1,7,31
cCSAus Certificate1055233
Code of Protection781D: Ex d IIC, Class I, Zone 1 AEx d IIC; Class I Div 1, Groups A,B,C,D
IP66, Enclosure Type 4X
781E: Ex e II, Class I, Zone 1, AEx e II
IP66, Enclosure Type 4X
Compliance StandardsCSA C22.2 No 0-10, 0.5, 30, 94; e 60079-0,1,7, E61241-1-1, UL50, 1203, UL60079-0,1,7
UL CertificateE253914
Code of Protection781D: Class I, Zone 1 AEx d IIB; Zone 20 AEx ta IIIC
781E: Class I, Zone 1, AEx e IIC;
EAC Certificate (Formerly GOST R, K & B)TC RU C-GB.AA87.B.00487
GOST R CertificatePOCC.GB.35.H00102
CCOE / PESO (India) CertificateP333688
INMETRO CertificateTÜV 12.133OU
NEPSI CertificateGYJ13.1139X (781D), GYJ13.1138X (781E)
RETIE Approval03866
Marine ApprovalsLRS: 01/00173
Continuous Operating Temperature781D: -60°C to +130°C
781E: -60°C to +130°C (-20°C to +60°C Nylon)
Ingress Protection Rating **781D: IP66 (when fitted with CMP sealing accessories)
781E: IP66
Available MaterialsBrass, Nickel Plated Brass, Aluminium, Stainless Steel, Nylon (781E only)
Accessories Included (781E only)Integral Entry Thread equipment interface ‘O’ ring seal, Castellated Locknut

Product Table

Metric

Ordering Reference
(781D)
Ordering Reference
(781E)
Thread SizeMinimum Thread LengthProtrusion Length “F”Across Flats DimensionAcross Corners DimensionsMax Installation Torque (Nm)
781DM2781EM2M20 x 1.515.012.730.033.07
781DM3781EM3M25 x 1.515.012.736.039.610
781DT1781ET1½” NPT19.912.730.033.07
781DT2781ET2¾” NPT20.212.736.039.610
Dimensions displayed in millimeters unless otherwise stated

Imperial

Ordering Reference
(781D)
Ordering Reference
(781E)
Thread SizeMinimum Thread LengthProtrusion Length “F”Across Flats DimensionAcross Corners DimensionsMax Installation Torque (Nm)
781DM2781EM2M20 x 1.50.590.501.181.307
781DM3781EM3M25 x 1.50.590.501.421.5610
781DT1781ET1½” NPT0.780.501.181.307
781DT2781ET2¾” NPT0.800.501.421.5610